Waveguide Type
- These are simple and conveniently variable type set-level attenuators to provide at least 20db (15 db in V&W Bands) of continuously variable attenuation.
- These consists of a movable lossy vane inside the section of a waveguide by means of a micrometer. The configuration of lossy-vane is so designed to obtain the low VSWR characteristics over the entire frequency band.
- These are meant for adjusting power level and isolating a source from the load etc.
Model No. | Frequency Range (GHz) | Max. VSWR | Av. Power (watts) | Max. Insertion Loss(db) | Waveguide Type (WR-) | Flange Type (UG- /U) |
MW-3008 | 1.7-2.6 | 1.1 | 10 | 0.2 | 430 | CPR-430 |
MW-3009 | 2.2-3.3 | 1.1 | 10 | 0.2 | 340 | CPR-340 |
MW-3010 | 2.6-3.95 | 1.1 | 5 | 0.2 | 284 | 53 |
MW-3011 | 3.3-4.9 | 1.1 | 5 | 0.2 | 229 | CPR-229 |
MW-3012 | 3.95-5.85 | 1.1 | 5 | 0.2 | 187 | 149A |
MW-3013 | 4.9-7.05 | 1.1 | 5 | 0.2 | 159 | CPR-159 |
MW-3014 | 5.85-8.2 | 1.1 | 3 | 0.2 | 137 | 344 |
MW-3015 | 7.05-10.0 | 1.1 | 3 | 0.2 | 112 | 51 |
MW-3016 | 8.2-12.4 | 1.1 | 2 | 0.2 | 90 | 39 |
MW-3017 | 10.0-15.0 | 1.1 | 2 | 0.2 | 75 | UDR/UBR 120 |
MW-3018 | 12.4-18.0 | 1.1 | 1 | 0.3 | 62 | 419 |
MW-3019 | 15.0-22.0 | 1.12 | 1 | 0.3 | 51 | Square 30.1MM |
MW-3020 | 18.0-26.5 | 1.15 | 0.5 | 0.4 | 42 | 595 |
MW-3021 | 26.5-40.0 | 1.15 | 0.5 | 0.4 | 28 | 599 |
MW-3022 | 50.0-75.0 | 1.15 | 0.5 | 0.5 | 15 | 385 |
MW-3023 | 75.0-110.0 | 1.15 | 0.5 | 0.5 | 10 | 387 |
- Model 3045 E-H Tee consists of a section of waveguide with both cseries and shunt waveguide arms, mounted at the exact mid point of main arm, Both ends of the section of waveguide and both arms are flanged on their ends.
- These Tees are employed in balanced mixers, automatic frequency control circuits and impedance measurement circuit etc. This becomes a four terminal device where one terminal is Isolated from the input terminal.
Model No. | Frequency Range (GHz) | Waveguide type (WR-) |
Flange type (UG-/U) |
OM – 3045a | 1.70-2.60 | 430 | CPR-430 |
OM – 3045b | 2.60-3.95 | 284 | 53 |
OM – 3045c | 3.95-5.85 | 187 | 149A |
OM – 3045d | 5.85-8.20 | 137 | 344 |
OM – 3045e | 8.20-12.4 | 90 | 39 |
OM – 3045f | 12.4-18.0 | 62 | 419 |
OM – 3045g | 18.0-26.5 | 42 | 595 |
OM – 3045h | 26.5-40.0 | 28 | 599 |
OM – 3045i | 50.0-75.0 | 15 | 385 |
OM – 3045j | 75.0-110.0 | 10 | 387 |
- Model MW – 2038 is a calibrated high gain amplifier tuned at one frequency to be used for measurement of VSWR, impedance and relative power levels. The meter indicates the signal level in proportion to the input, which is calibrated directly in VSWR and db.
- Input Selector Switch is provided for NORMAL and EXPAND range.
Specification:
Amplifier type | High gain tuned at one frequency. |
Frequency | 1000 Hz ± 2%. |
Sensitivity | 0.1 microvolt at 200 ohms for full scale. |
Band-width | 25-30 Hz. |
Noise-level | Less than 0.02 microvolt. |
Range | 70 db min. in 10 db steps. |
Accuracy | ± 0.15 db on one range. |
Meter-Linearity | 1% of full scale. |
Scale-Selector | Normal, Expand. |
Gain-Control | ‘Coarse’ & ‘Fine’. |
Input | BNC (F), 200 ohms impedance |
Mains Power | 230 V, 50 Hz |
Standard Accessories | i) Instruction Manual (1 No.)
ii) Mains Cord (1 No.) iii) Coax, cable BNC to BNC (1 No.) iv) Spare Fuse (2 Nos.) |
The SWR meter or VSWR (voltage standing wave ratio) meter measures the standing wave ratio in a transmission line. The meter can be used to indicate the degree of mismatch between a transmission line and its load, or evaluate the effectiveness of impedance matching efforts.
Specifications
Input Power Supply | 220 VAC ±10%, 50 Hz |
Input Connector | BNC(F) |
Amplifier type | High gain tuned at 1kHz |
Input Frequency | 1000Hz ± 2% |
Bandwidth(3db) | 50Hz |
Input Selector | Xtal High (200KΩ) impedance
Xtal Low (200Ω) impedance Bolo 200 Ω, 4.5 mA Bias Bolo 200 Ω, 8.7 mA Bias |
Sensitivity | <1 uV for full scale deflection at xtal low/Bolo position |
Range | Over 70db (60db in 10db steps, 10db through coarse adjustment, 2db through fine adjustment) |
Accuracy | ± 0.2 db per 10 db step |
Meter Scales | SWR 1-4, SWR 3-10 Expanded SWR 1-1.3 db Expanded db 0-2 |
Mode | Normal/Expanded |
Gain Control | Coarse adjustment 10db minimum
Fine adjustment 2db minimum |
Recorder output | Through BNC(F) connector |
Recorder output level | 1V for full scale deflection of meter |
Mechanical dimensions | 26(L) X 13(H) X 20.4(D) cms |
Weight | 2.7 kg |
Standard Accessories | i. Mains Cable (1 )
ii. Coaxial Cable BNC-BNC (1) iii. Spare fuses (2) iv. Instruction Manual |
KLYSTRON power supply solid state MW- 2030
Klystron power supply, Model MW – 2030 is a state of art solid state solid state, regulated power supply for operating low power klystrons.
Feature
- Regulated beam supply, Repeller and Filament supply voltages.
- Overload TRIP protection for beam supply output.
- LED digital metering for beam voltage, current and repeller voltage.
- Standby mode.
- Ultra compact and reliable.
- Modular construction for easy maintenance.
In addition to AM and FM modulation of Beam Current a provision for externally modulating the klystron supply with desired signal waveform has been provided. A carefully handling of instrument will provided years of trouble free service.
Specifications
Input Voltage | 230VAC, ±10%, 50 Hz |
Beam Supply | Voltage : 240- 400 Vdc, Variable Current : 50 mA Regulation : 0.5% for 10% I/P variation Ripple: <5mv RMS |
Repeller Supply | 10-270 Vdc, Variable Regulation : 0.25% for 10% I/P variation |
Filament Supply | 6.3V dc |
Over-load Trip Current | 65 mA |
Modulation Frequency Range Amplitude External |
AM (Square) FM (Saw -Tooth) 500-2500 Hz 150-300 Hz 0-110 V 0-65 V Through external Modulating Signal |
Display | Digital display for (1) Beam voltage
(2) Beam Current, |
Standby Mode | Only Heater Supply ON |
Connectors | (1) 8-Pin Octal Socket for Klystron,
(2) BNC (F) for external Modulation (4) BNC (F) for Saw-tooth Monitoring |
Mechanical Dimensions | 26.5(L) X 13(H) X 20(D) Cms Weight – 5.6 kg |
Standard Accessories | i) Mains Cable (1 No.) ii) Coaxial Cable BNC – BNC (1 No.) iii) Spare Fuses (2 Nos.) iv) Instruction Manual (1 No.) |
- Model MW-2025 Gunn Power Supply comprises of regulated D.C. power supply and a square wave generator, designed to operate Gunn-Oscillator etc. and Pin-Modulator model 451 simultaneously.
- The D.C. Voltage is variable from 0 to 12.0 volts. The front-panel digital meter monitors the Gunn voltage and the current drawn by the Gunn-diode.
- The square waves of generators is variable from 0 to 1 0 Volts in amplitude and from 850 to 1150 Hz in frequency.
- The power supply has been so designed to protect Gunn diode from reverse voltage application, over transient and low frequency oscillations by the negative resistance of the Gunn-diode.
Specification
Model No. | X-110 |
Gunn Bias Voltage | 0 to 12 V |
Current | 0 to 1.0 A (Max.) |
Regulation | 0.2% for ± 10% mains variation |
Ripple | 2 mv (rms) |
Modulation Frequency | 850 to 11 50 Hz, Square wave |
Mod. Amplitude | 0 to 10.0 V (peak to peak) |
Output Connectors | BNC (F) for Gunn Bias UHF (F) for Pin-mod. |
Mains Supply | 230 V, 50 Hz, 25 watts approx. |
Standard Accessories | (i) Mains Cable ( 01 No.)
(ii) Coax. Cable BNC to BNC (01 No.) (iii) Coax. Cable BNC to UHF (01 No.) (iv) Spare Fuses (02 Nos.) (v) Instruction Manual (01 No.) |
GUNN power Supply MW- 2022
- Model MW- 2022 Gunn Power Supply has been designed to operate high frequency Gunn Oscillators and where PIN Modulators are not available, In this supply variable frequency square Wave modulation is provided on the bias supply itself.
- Front panel digital meter reads the Gunn Bias Voltage and the current drawn by the Gunn-Diode through a switch.
- This consists of a regulated D.C. power supply 2.0 to 1 2.0 V variable and a square wave generator of variable frequency 850 to 1150 Hz.
Specification:
Model No. | MW- 2022 |
Gunn Bias Voltage | 1 to 1 2 V |
Current | 0 to 1.0 A |
Regulation | 0.2% for ± 1 0 mains variation |
Modulation Selector Switch | CW& INT. |
Modulation Frequency | 850 to 11 50 Hz square-wave |
Output Connector | BNC (F) for Gunn Bias |
Digital Panel Meter | Read Gunn bias voltage & current drawn |
Mains | 230 V, 50 Hz 35 Watts |
Std. Accessories | i) Mains Cable (1 No.)
ii) Coax. Cable BNC to BNC (1 No.) iii) Spare Fuse (2 Nos.) iv) Instruction Manual (1 No.) |
- These Gunn oscillator are solid state microwave energy generators. These consists of waveguide cavity flanged on one end and micrometer driven plunger fitted on the other end. A gunn-diode is mounted inside the waveguide with BNC (F) connector for D.C. Bias.
- Each Gunn Oscillator is supplied with calibration certificate giving frequency Vs. micrometer reading at 200MHz intervals.
Model No. | Frequency Range (Ghz) | Min. Output Power (mW) | Waveguide Type (WR-) | Flange Type (UG-/U) |
MW-3001 | 4.4-4.9 | 10 | 187 | 149 A |
MW-3002 | 6.5-7.5 | 10 | 137 | 344 |
MW-3003 | 8.6-11.6 | 10 | 90 | 39 |
MW-3004 | 12.6-15.5 | 10 | 62 | 419 |
MW-3005 | 20.0-24.5 | 10 | 42 | 595 |
MW-3006 | 34.0-36.0 | 10 | 28 | 599 |
- Model MW-2016 is an Automatic Self Balancing Power Meter 0-18 GHz. It measures RF Power with the help of temperature compensated Thermistor Mount from 10;uW to 10mW full scale with 1 % accuracy from 10 MHz to 40 GHz (depend upon type of Thermistor Mount).
- With calibration factor control switch, MW-2016 normalizes the Power Meter reading to compensate the efficiency of used Thermistor Mount.
- MW-2016 has provision for substitution measurements and Power Meter calibration. Output is provided for recorder or Digital Voltmeter readout.
Specification:
Instrument Type | Model MW-2016 , Digital Power Meter |
Power Range | Four Ranges With Full Scale Readings of 10uW, 1 00u.W, 1mW and 10mW |
Accuracy | ± 1 % of fullscale on Milliwatt range And ± 2.5% on Micro Watt Range |
Fine Zero | Automatic, operated by Front Panel Switch |
Zero Carryover | Less than 0.5% of fullscale when zeroed on most Sensitive Range |
Calibration | 1 1 -position Switch normalizes Meter Factor Control Readings to account for Thermister Range |
Recorder | Proportional to indicated Power with output 1 Volt corresponding to fullscale 1 kOhm output Impedance. |
Bridge Ouput | (VRF and VComp), Direct Connection to Thermistor Bridges: Used in Calibration and Precision power measurement |
POWER | 230v ± 10% AC 50Hz, 10 Watts |
SIZE | 20x15x25 cm |
Standard Accessories | (i) Mains Cable – 1 No.
(ii) Spare Fuse – 2 Nos. (iii) Instruction Manual -1 No. |
Optional Accessories | (i) Connecting Cable for Thermistor Mount at AT-211 B is available on extra cost.
(ii) Temperature compensated Thermistor Mount Model: HP-8478B, 10MHz – 18 Ghz (Make Agilient or else) may be supplied. |
Direct Reading Type
- Direct reading frequency meter are absorption type frequency meter to give direct frequency on the dial provided. These are recommended for use whenever quick determination of frequency and easy readings are desired in laboratory and production testing.
- These consists of a section of waveguide connected to a tunable resonant cavity of high Q. The cavity absorbs some power at resonant frequency. These are designed to have 5 MHz resolution & off resonance VSWR of 1.01.
Model No | MW-3031 | MW-3032 | MW-3033 | MW-3034 | MW-3035 | MW-3036 |
Frequency Range (Ghz) | 3.95-5.8 | 5.85-8.2 | 8.2-12.4 | 12.4-18.0 | 18.0-26.0 | 26.0-40.0 |
Waveguide Type (WR-) | 187 | 137 | 90 | 62 | 42 | 28 |
Flange Type (UG-/U) | 149A | 344 | 39 | 419 | 595 | 599 |
Following Experiments can be performed using this training kits.
- To study the Characteristics of Reflex Klystron.
- To study Frequency, Guide Wavelength & free Space Wavelength.
- To measure the SWR & Reflection Coefficient.
- To measure Impedence of a load.
- This is the basic Microwave test bench using klystron Source.
Compact microwave training kits VX-2001 consists of the following Components & Instruments :-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Slotted Section | 1 |
Tunable Probe | 1 |
Detector Mount | 1 |
Movable Short | 1 |
Matched Termination | 1 |
VSWR Meter, Solid State | 1 |
Waveguide Stands | 4 |
Slide Screw Tuner | 1 |
Cooling Fan | 1 |
BNC to BNC Cable | 1 |
BNC to Open Cable | 1 |
Fixed Short | 1 |
Following Experiments can be performed using this Training kit –
- To understand basic setup & introduction of given system.
- To study reflection in Microwaves.
- To study refraction through prism.
- To study polarization using microwaves.
- To study Double-Slit Interference.
- To study Lloyds Mirror.
- To study Fabry-Perot Interferometer.
- To study Michelson Interferometer.
- To study Fiber Optics.
- To measure Brewster’s Angle.
- To study Bragg Diffraction using crystal lattic structure.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Gunn Power Supply | 1 |
Gunn Oscillator | 1 |
Variable Attenuator | 1 |
Horn Antenna | 2 |
Goniometer / Turn Table | 1 |
Receiver | 1 |
Reflector Plates | 2 |
Partial Reflector | 2 |
Prism | 1 |
Lattic Structure | 1 |
Polyfoam sheet | 1 |
Cooling Fan | 1 |
BNC TO BNC Cable | 1 |
- Microwave radiations are mono-chromatic, Plane Polarised and Coherent and they behave like waves. Many laboratory experiments in optics can be performed easily with simple microwave equipments, Reflection, Refraction and polarization including to prove Bragg’s Law can be performed with this microwave Diffraction Spectrometer.
- It consists of a Goniometer with one stationary and other rotatable arm. Each of these arms has to adjustable stands. These stands hold the transmitting horn on one end and the receiver horn on the other.
- The Polyfoam containing the steel balls structure is kept in the center. A 0-360° found scale with a pointer is provided to read the position of rotatable arm.
Experiment Performed
- To prove Bragg’s Law using Microwave Diffraction Spectrometer.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Variable Attenuator | 1 |
Pyramidal Waveguide Horn | 2 |
Detector Mount | 1 |
Mechanical Turn Table with crystal Structure i.e. Diffraction Spectrometer | 1 |
Waveguide Stands | 2 |
Cooling Fan | 1 |
Direct Reading Frequency Meter | 1 |
Isolator | 1 |
Coaxial to Waveguide Adapter | 1 |
Coaxial Cable N to N | 1 |
VSWR Meter | 1 |
Experiment Performed
- To Study the Faraday Rotation Effects and its properties.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Faraday Rotation Setup consist of following components :-
a) Circular to Waveguide Transition b) Round Waveguide with Magnetic Coil c) DC Power Supply d) Ferrite Fitted inside the round Waveguide e) Round Waveguide Stands f) Rotary Joint, 1- Type |
2 1 1 1 2 1 |
Detector Mount | 1 |
VSWR Meter, Solid State | 1 |
Waveguide Stands | 1 |
Cooling Fan | 1 |
Following experiments can be performed using this training kit –
- To study Magic Tee, Directional Couplers, Isolators & Circulators
- To study the Characteristics of detector diode.
- To study Attenuation measurement.
- To Study the return loss measurement.
- To study the Characteristics of Gunn Diode.
- To study Frequency, Guide Wavelength & free Space Wavelength.
- To measure the SWR & Reflection Coefficient.
- To measure Impedance of a load.
- To study the Characteristics of Reflex Klystron.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Fixed Attenuator 3,6,10 db | 3 |
Detector Mount | 1 |
Movable Short | 1 |
Slotted Section | 1 |
Tunable Probe | 1 |
VSWR Meter, Solid State | 1 |
Waveguide Stands | 4 |
Slide Screw Tuner | 1 |
Cooling Fan | 1 |
BNC to BNC Cable | 1 |
Matched Termination | 2 |
Multi hole D. Coupler 3,10,20 db | 3 |
Three Port Circulator, Y- Type | 1 |
E-Plane Tee | 1 |
H- Plane Tee | 1 |
Magic Tee/ E-H Tee | 1 |
Gunn Power Supply | 1 |
Gunn Oscillator | 1 |
Pin Modulator | 1 |
Fixed Short | 1 |
Smith Chart of 100 Pcs. | 1 |
Following Experiments can be performed using this training kit –
- To study Magic Tee, Directional Couplers, Isolators & Circulators.
- To study the characteristics of detector diode.
- To study Attenuation measurement.
- To study the return loss measurement.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Slotted Section | 1 |
Tunable Probe | 1 |
Detector Mount | 1 |
Fixed attenuator 3, 6, 10 db | 3 |
Magic Tee | 1 |
Movable Shot | 1 |
Waveguide Stand | 4 |
Slide Screw Tuner | 1 |
Cooling Fan | 1 |
BNC to BNC Cable | 1 |
Matched Termination | 2 |
Multihole D. Coupler 3, 10, 20 db | 3 |
Three port circulator, Y type | 1 |
E- Plane Tee | 1 |
H- Plane Tee | 1 |
VSWR Meter Solid State | 1 |
Following Experiments can be performed using this training kit –
- To measure dielectric constant of solids.
- To measure dielectric constant of liquids.
- To measure phase shift.
- To measure “Q” of a cavity.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Slotted Section | 1 |
Tunable Probe | 1 |
Detector Mount | 1 |
Solid dielectric cell | 1 |
Liquid dielectric cell | 1 |
VSWR Meter, Solid State | 1 |
Waveguide Stands | 4 |
Waveguide Cavity | 1 |
Cooling Fan | 1 |
BNC to BNC Cable | 1 |
Precision movable short | 1 |
Waveguide Phase Shifter | 1 |
Solid Dielectric of Teflon, Nylon, Ebonite, Perspex & wax in 10, 20, 30 MM length each | 1 |
Experiment Performed:
- To measure the polar and linear pattern of Horn Antenna using microprocessor based turn table.
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1. |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1. |
Microprocessor based Turn Table with Computer Interface for Polar pattern measurement | 1 |
Pyramidal Horn Antenna | 2 |
E-Plane Bend | 2 |
Detector Mount | 1 |
VSWR Meter, Solid State | 1 |
Waveguide Stands | 4 |
Cooling Fan | 1 |
Wg with flanges, L = 15 cm | 1 |
Optional Accessories | |
Pick-up Horn | 1 |
Broad-wall slot Antenna | 1 |
Narrow wall slot antenna | 1 |
Dielectric Antenna | 1 |
E- Plane Sectoral Horn | 1 |
H- Plane Sectoral Horn | 1 |
Parabolic Dish | 1 |
Waveguide Twist | 1 |
Precision Movable Short | 1 |
Helix Antenna | 1 |
Matched Termination | 1 |
Following Experiments can be performed using this training kit –
To Plot the polar pattern & gain characteristics of following Antennas
- Pyramidal Horn
- Pick Up Horn
- Slotted Wave Guide Antenna (Narrow & Broad -Wall)
- Dielectric Antenna
- Sectorial Horns (E & H – Plane)
- Parabolic Dish
- Heliax Antenna
Compact microwave training kits consists of the following Components & Instruments:-
Experimental set up Contain | Quantity |
Klystron Power Supply | 1 |
Klystron Mount | 1 |
Klystron Tube | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Detector Mount | 1 |
VSWR Meter, Solid State | 1 |
T-Circulator | 1 |
Coaxial to W/G Adaptor | 2 |
Coaxial Cable N to N | 1 |
Waveguide Twist | 1 |
Precision Movable Short | 1 |
Waveguide Stand | 4 |
Waveguide Bend, 90 degree | 2 |
Cooling Fan | 1 |
Radiation – Pattern Turn Table | 1 |
Tripod Stand for Antenna | 1 |
Various Type of Antenna | |
Standard Gain Horn | 1 |
Pyramidal Wg. Horn | 1 |
Pick up Horn | 1 |
Broad Wall slot Antenna | 1 |
Narrow Wall slot Antenna | 1 |
Dielectric Antenna | 1 |
E- Plane Sectoral Antenna | 1 |
H- Plane Sectoral Antenna | 1 |
Parabolic Dish | 1 |
Helix Antenna | 1 |
Following Experiments can be performed using this training kits –
- To study characteristics of Gunn Diode.
- To Study frequency, Guide wavelength & free space wavelength.
- To measure the SWR & Reflection coefficient.
- To measure Impedence of a load.
Compact microwave training kits consists of the following Components & Instruments :-
Experimental set up Contain | Quantity |
Gunn Power Supply | 1 |
Gunn Oscillator | 1 |
Pin Modulator | 1 |
Isolator | 1 |
Frequency Meter, Direct Reading Type | 1 |
Variable Attenuator | 1 |
Slotted Section | 1 |
Tunable Probe | 1 |
Detector Mount | 1 |
Movable Short | 1 |
Matched Termination | 1 |
VSWR Meter, Solid State | 1 |
Waveguide Stands | 4 |
Slide Screw Tuner | 1 |
Cooling Fan | 1 |
BNC to BNC Cable | 1 |
BNC to Open Cable | 1 |
Fixed Short | 1 |
Smith Chart of 100 Pcs. | 1 |